{"title":"Resistance\/Battery Meters","description":"\u003cp\u003e\u003cspan\u003eResistance meters can detect electrical defects by measuring the resistance of electrical components and cables.The four-terminal method provided by Hioki’s resistance meters makes it possible to measure low resistance values while ignoring the effects of contact and wiring resistance. Meanwhile, battery testers assess the internal resistance and impedance of batteries, a growing market, contributing to quality improvement, degradation diagnostics, and reduced inspection time.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"resistance-meter-rm3548-50","title":"RESISTANCE METER RM3548-50","description":"\u003cdiv class=\"unique-item-02 js-tab-01 set-tab\"\u003e\n\u003cdiv id=\"specifications\" class=\"item js-tab-item set-tab-item current\" role=\"tabpanel\" aria-labelledby=\"tab-item3\"\u003e\n\u003ch4 class=\"hdg2-04\"\u003eBasic specifications\u003c\/h4\u003e\n\u003cdiv\u003eAccuracy guaranteed: 1 year\u003c\/div\u003e\n\u003cdiv id=\"tablefield-wrapper-paragraph-41124-field_table_spec-0\" class=\"tablefield-wrapper\"\u003e\n\u003cdiv class=\"table-scroll-01\"\u003e\n\u003cdiv class=\"inner\"\u003e\n\u003ctable class=\"table-01\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_0 col_0\"\u003eResistance range\u003c\/th\u003e\n\u003ctd class=\"row_0 col_1\" colspan=\"6\"\u003e3 mΩ (3.5000 mΩ display Max., 0.1 µΩ resolution) to 3 MΩ range (3.5000 MΩ display Max., 100 Ω resolution), 10 steps\u003cbr\u003eMeasurement accuracy: ±0.020 % rdg. ±0.007 % f.s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_1 col_0\"\u003eTesting current\u003c\/th\u003e\n\u003ctd class=\"row_1 col_1\" colspan=\"6\"\u003e[at 3 mΩ range] 1 A DC to [at 3 MΩ range] 500 nA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_2 col_0\"\u003eOpen-terminal voltage\u003c\/th\u003e\n\u003ctd class=\"row_2 col_1\" colspan=\"6\"\u003e5.5 V DC max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_3 col_0\"\u003eTemperature measurement\u003c\/th\u003e\n\u003ctd class=\"row_3 col_1\" colspan=\"6\"\u003e-10.0°C to 99.9°C, accuracy: ±0.5°C (Temperature Sensor Z2002 and RM3548-50 combined accuracy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_4 col_0\"\u003eMeasurement speed\u003c\/th\u003e\n\u003ctd class=\"row_4 col_1\" colspan=\"6\"\u003eFixed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_5 col_0\"\u003eDisplay refresh rate\u003c\/th\u003e\n\u003ctd class=\"row_5 col_1\" colspan=\"6\"\u003eWithout OVC: approx. 100 ms\u003cbr\u003eWith OVC: approx. 230 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_6 col_0\"\u003eFunctions\u003c\/th\u003e\n\u003ctd class=\"row_6 col_1\" colspan=\"6\"\u003eTemperature correction, temperature conversion, offset voltage compensation (OVC), comparator (ABS\/REF%), length conversion, judgment sound setting, auto hold, auto power save (APS), Averaging, panel store\/panel load, USB communication interface (RM3548-50 internal memory is recognized as a mass storage device when connected to a PC), wireless communication via Bluetooth® (Z3210 is necessary)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_7 col_0\"\u003eMemory storage\u003c\/th\u003e\n\u003ctd class=\"row_7 col_1\" colspan=\"6\"\u003eNumber of recordable data points: up to 1000 for manual\/auto, up to 6000 for interval\u003cbr\u003eInterval: 0.2 s to 10.0 s (0.2 s step)\u003cbr\u003eAcquisition of data from memory: display, USB mass storage (CSV, TXT files)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_8 col_0\"\u003ePower supply\u003c\/th\u003e\n\u003ctd class=\"row_8 col_1\" colspan=\"6\"\u003eLR6 alkaline batteries × 8\u003cbr\u003eHR6 nickel-metal hydride batteries × 8\u003cbr\u003eContinuous use: approx. 10 hours (under our company’s conditions)\u003cbr\u003eRated voltage: 5 VA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_9 col_0\"\u003eDimensions and weight\u003c\/th\u003e\n\u003ctd class=\"row_9 col_1\" colspan=\"6\"\u003eApprox. 199 mm (7.8 in.) W × 132 mm (5.2 in.) H × 60 mm (2.4 in.) D (including the protector)\u003cbr\u003eApprox. 890 g (31.4 oz) (including the batteries and protector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_10 col_0\"\u003eIncluded accessories\u003c\/th\u003e\n\u003ctd class=\"row_10 col_1\" colspan=\"6\"\u003eClip Type Lead L2107 ×1, Temperature Sensor Z2002 ×1, Protector Z5041 ×1, LR6 alkaline battery ×8, Instruction Manual ×1, USB Cable (A to mini-B) ×1, Strap ×1, Spare fuse ×1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hioki-nz","offers":[{"title":"Default Title","offer_id":47212627689643,"sku":null,"price":2500.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0765\/7789\/8667\/files\/RM3548-50_01_Copy.jpg?v=1781061112"},{"product_id":"battery-tester-bt3554-51","title":"BATTERY TESTER BT3554-51","description":"\u003ch2 class=\"hdg2-04\"\u003eBasic specifications\u003c\/h2\u003e\n\u003cdiv\u003eAccuracy guaranteed: 1 year\u003c\/div\u003e\n\u003cdiv id=\"tablefield-wrapper-paragraph-32446-field_table_spec-0\" class=\"tablefield-wrapper\"\u003e\n\u003cdiv class=\"table-scroll-01\"\u003e\n\u003cdiv class=\"inner\"\u003e\n\u003ctable class=\"table-01\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_0 col_0\"\u003e　\u003c\/th\u003e\n\u003ctd class=\"row_0 col_1\"\u003eBT3554-50\u003c\/td\u003e\n\u003ctd class=\"row_0 col_2\"\u003eBT3554-51\u003c\/td\u003e\n\u003ctd class=\"row_0 col_3\" colspan=\"4\"\u003eBT3554-52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_1 col_0\"\u003eResistance measurement range\u003c\/th\u003e\n\u003ctd class=\"row_1 col_1\" colspan=\"6\"\u003e3 mΩ (max. display 3.100 mΩ, resolution 1 μΩ) to 3 Ω (max. display 3.100 Ω, resolution 1 mΩ), 4 ranges\u003cbr\u003eAccuracy: ±0.8 % rdg ±6 dgt (3 mΩ range: ±1.0 % rdg ±8 dgt)\u003cbr\u003eTesting source frequency: 1 kHz ±30 Hz\u003cbr\u003eWith function for avoiding noise frequency enabled: 1 kHz ±80 Hz\u003cbr\u003eTesting current: 160 mA (3m\/30 mΩ range), 16 mA (300 mΩ range), 1.6 mA (3 Ω range)\u003cbr\u003eOpen terminal Voltage: 5 V peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_2 col_0\"\u003eVoltage measurement range\u003c\/th\u003e\n\u003ctd class=\"row_2 col_1\" colspan=\"6\"\u003e± 6 V (max. display ±6.000 V, resolution: 1 mV) to ± 60 V (max. display ±60.00 V, resolution: 10 mV), 2 ranges, Accuracy: ±0.08 % rdg ±6 dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_3 col_0\"\u003eTemperature measurement accuracy\u003c\/th\u003e\n\u003ctd class=\"row_3 col_1\" colspan=\"6\"\u003eMeasurement range: -10°C to 60°C (14°F to 140°F), Maximum display: 60.0°C (140.0°F), Resolution 0.1°C (0.1°F), Measurement accuracy*: ±1.0°C (±1.8°F)\u003cbr\u003e* When using the Clip Type Lead with Temperature Sensor 9460.\u003cbr\u003e* When using the Temperature Probe 9451, add ±0.5°C (±0.9°F) (cable length: 1.5 m [59.1\"]).\u003cbr\u003e* When using the Temperature Probe 9451S, add ±0.5°C (±0.9°F) (cable length: 0.1 m [3.94\"]).\u003cbr\u003eBT3554-50 standalone accuracy with simulated input: ±0.5°C (±0.9°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_4 col_0\"\u003eAbsolute max. input voltage\u003c\/th\u003e\n\u003ctd class=\"row_4 col_1\" colspan=\"6\"\u003e60 V DC max. (No AC input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_5 col_0\"\u003eMeasurement time\u003c\/th\u003e\n\u003ctd class=\"row_5 col_1\" colspan=\"6\"\u003e100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_6 col_0\"\u003eResponse time\u003c\/th\u003e\n\u003ctd class=\"row_6 col_1\" colspan=\"6\"\u003eApprox. 1.6 sec.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_7 col_0\"\u003eComparator\u003c\/th\u003e\n\u003ctd class=\"row_7 col_1\" colspan=\"6\"\u003eCompares measured values with set threshold values to make judgments and reports them to the user.\u003cbr\u003eJudgment notification method: Results are displayed as shown below (segment) and beeping tones sound\u003cbr\u003eWhen the Voltage value (high): Resistance value (low)= PASS, Resistance value (medium)= WARNING, Resistance value (high)= FAIL\u003cbr\u003eWhen the Voltage value (low): Resistance value (low)= WARNING, Resistance value (medium)= WARNING, Resistance value (high)= FAIL\u003cbr\u003eIf the judgment result is WARNING or FAIL, the audio tone is accompanied by a red backlight.\u003cbr\u003eUser-selectable voltage judgment method: ABS (absolute value judgment), POL (polarity judgment )\u003cbr\u003eSavable settings: 200 tables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_8 col_0\"\u003eMemory functionality\u003c\/th\u003e\n\u003ctd class=\"row_8 col_1\" colspan=\"6\"\u003eOperation: Save, load, and delete measurement data, Save and delete profile information, Number of data sets: 6000, Memory architecture: 500 data sets per unit (12 units)\u003cbr\u003eSaved data: Saved measurement data is linked to profile information.\u003cbr\u003e\u003cbr\u003e1. Measurement data: Data can be saved, loaded, and deleted by operating the instrument.\u003cbr\u003e-1. Date and time\u003cbr\u003e-2. Resistance value, voltage value, and temperature\u003cbr\u003e-3. Comparator threshold value and judgment result\u003cbr\u003e\u003cbr\u003e2. Profile information: Profile information can be saved, loaded, and deleted using a supported application (GENNECT Cross or GENNECT One).\u003cbr\u003e-1. Profile numbers: 1 to 100 (Data (2), (3), and (4) below are saved for each profile number)\u003cbr\u003e-2. Location: User-defined comment such as location of UPS\u003cbr\u003e-3. Device information: User-defined comment such as UPS management number\u003cbr\u003e-4. Battery number: 1 to 500 (start number, end number)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_9 col_0\"\u003eMeasurement Navigator\u003c\/th\u003e\n\u003ctd class=\"row_9 col_1\" colspan=\"6\"\u003eOperation: Announces the next battery number to be measured via a screen display and audio guidance.\u003cbr\u003eAudio output is generated by a connected mobile device when using the Z3210 and a supported application (GENNECT Cross).\u003cbr\u003ePreparations: Profile information that's been registered with a supported application (GENNECT Cross or GENNECT One) must be transferred to the instrument.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_10 col_0\"\u003eCommunication interface\u003c\/th\u003e\n\u003ctd class=\"row_10 col_1\" colspan=\"6\"\u003eUSB\u003cbr\u003eBluetooth® wireless communications (when Z3210 installed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_11 col_0\"\u003eOther functions\u003c\/th\u003e\n\u003ctd class=\"row_11 col_1\" colspan=\"6\"\u003eTemperature measurement (-10.0 to 60.0 °C), Zero-adjustment, Hold, Auto-hold, Auto-memory, Auto-power-save, Clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_12 col_0\"\u003ePower supply\u003c\/th\u003e\n\u003ctd class=\"row_12 col_1\" colspan=\"6\"\u003eLR6 (size AA) alkaline battery ×8\u003cbr\u003eRated supply voltage: 1.5 V DC × 8\u003cbr\u003e(Nickel metal hydride batteries may be used. However, the battery life display is not supported in this configuration.)\u003cbr\u003eContinuous operating time: Approx. 8.3 hr. (without Z3210 installed), Approx. 8.2 hr. (with Z3210 installed and wireless communications active)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_13 col_0\"\u003eDimensions and mass\u003c\/th\u003e\n\u003ctd class=\"row_13 col_1\" colspan=\"6\"\u003e199 mm (7.83 in)W × 132 mm (5.20 in)H × 60.6 mm (2.39 in)D (with protector), 960 g (33.9 oz) (including batteries and protector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_14 col_0\"\u003eIncluded accessories\u003c\/th\u003e\n\u003ctd class=\"row_14 col_1\" colspan=\"6\"\u003eCarrying Case C1014 ×1, Protector Z5041 ×1, Fuse Set Z5050 ×1, 0 Adj Board ×1, Neck strap ×1, USB cable ×1, AA alkaline battery (LR6) ×8, User Manual ×1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_15 col_0\"\u003e　\u003c\/th\u003e\n\u003ctd class=\"row_15 col_1\"\u003eInstrument only\u003c\/td\u003e\n\u003ctd class=\"row_15 col_2\"\u003eWith Pin Type Lead 9465-10\u003c\/td\u003e\n\u003ctd class=\"row_15 col_3\" colspan=\"4\"\u003eWith Pin Type Lead L2020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hioki-nz","offers":[{"title":"Default Title","offer_id":47239467368619,"sku":null,"price":4510.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0765\/7789\/8667\/files\/BT3554-50__3png.png?v=1781655126"},{"product_id":"battery-tester-bt-3554-52","title":"BATTERY Tester BT 3554-52","description":"\u003ch2 class=\"hdg2-04\"\u003eBasic specifications\u003c\/h2\u003e\n\u003cdiv\u003eAccuracy guaranteed: 1 year\u003c\/div\u003e\n\u003cdiv id=\"tablefield-wrapper-paragraph-32446-field_table_spec-0\" class=\"tablefield-wrapper\"\u003e\n\u003cdiv class=\"table-scroll-01\"\u003e\n\u003cdiv class=\"inner\"\u003e\n\u003ctable class=\"table-01\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_0 col_0\"\u003e　\u003c\/th\u003e\n\u003ctd class=\"row_0 col_1\"\u003eBT3554-50\u003c\/td\u003e\n\u003ctd class=\"row_0 col_2\"\u003eBT3554-51\u003c\/td\u003e\n\u003ctd class=\"row_0 col_3\" colspan=\"4\"\u003eBT3554-52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_1 col_0\"\u003eResistance measurement range\u003c\/th\u003e\n\u003ctd class=\"row_1 col_1\" colspan=\"6\"\u003e3 mΩ (max. display 3.100 mΩ, resolution 1 μΩ) to 3 Ω (max. display 3.100 Ω, resolution 1 mΩ), 4 ranges\u003cbr\u003eAccuracy: ±0.8 % rdg ±6 dgt (3 mΩ range: ±1.0 % rdg ±8 dgt)\u003cbr\u003eTesting source frequency: 1 kHz ±30 Hz\u003cbr\u003eWith function for avoiding noise frequency enabled: 1 kHz ±80 Hz\u003cbr\u003eTesting current: 160 mA (3m\/30 mΩ range), 16 mA (300 mΩ range), 1.6 mA (3 Ω range)\u003cbr\u003eOpen terminal Voltage: 5 V peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_2 col_0\"\u003eVoltage measurement range\u003c\/th\u003e\n\u003ctd class=\"row_2 col_1\" colspan=\"6\"\u003e± 6 V (max. display ±6.000 V, resolution: 1 mV) to ± 60 V (max. display ±60.00 V, resolution: 10 mV), 2 ranges, Accuracy: ±0.08 % rdg ±6 dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_3 col_0\"\u003eTemperature measurement accuracy\u003c\/th\u003e\n\u003ctd class=\"row_3 col_1\" colspan=\"6\"\u003eMeasurement range: -10°C to 60°C (14°F to 140°F), Maximum display: 60.0°C (140.0°F), Resolution 0.1°C (0.1°F), Measurement accuracy*: ±1.0°C (±1.8°F)\u003cbr\u003e* When using the Clip Type Lead with Temperature Sensor 9460.\u003cbr\u003e* When using the Temperature Probe 9451, add ±0.5°C (±0.9°F) (cable length: 1.5 m [59.1\"]).\u003cbr\u003e* When using the Temperature Probe 9451S, add ±0.5°C (±0.9°F) (cable length: 0.1 m [3.94\"]).\u003cbr\u003eBT3554-50 standalone accuracy with simulated input: ±0.5°C (±0.9°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_4 col_0\"\u003eAbsolute max. input voltage\u003c\/th\u003e\n\u003ctd class=\"row_4 col_1\" colspan=\"6\"\u003e60 V DC max. (No AC input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_5 col_0\"\u003eMeasurement time\u003c\/th\u003e\n\u003ctd class=\"row_5 col_1\" colspan=\"6\"\u003e100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_6 col_0\"\u003eResponse time\u003c\/th\u003e\n\u003ctd class=\"row_6 col_1\" colspan=\"6\"\u003eApprox. 1.6 sec.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_7 col_0\"\u003eComparator\u003c\/th\u003e\n\u003ctd class=\"row_7 col_1\" colspan=\"6\"\u003eCompares measured values with set threshold values to make judgments and reports them to the user.\u003cbr\u003eJudgment notification method: Results are displayed as shown below (segment) and beeping tones sound\u003cbr\u003eWhen the Voltage value (high): Resistance value (low)= PASS, Resistance value (medium)= WARNING, Resistance value (high)= FAIL\u003cbr\u003eWhen the Voltage value (low): Resistance value (low)= WARNING, Resistance value (medium)= WARNING, Resistance value (high)= FAIL\u003cbr\u003eIf the judgment result is WARNING or FAIL, the audio tone is accompanied by a red backlight.\u003cbr\u003eUser-selectable voltage judgment method: ABS (absolute value judgment), POL (polarity judgment )\u003cbr\u003eSavable settings: 200 tables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_8 col_0\"\u003eMemory functionality\u003c\/th\u003e\n\u003ctd class=\"row_8 col_1\" colspan=\"6\"\u003eOperation: Save, load, and delete measurement data, Save and delete profile information, Number of data sets: 6000, Memory architecture: 500 data sets per unit (12 units)\u003cbr\u003eSaved data: Saved measurement data is linked to profile information.\u003cbr\u003e\u003cbr\u003e1. Measurement data: Data can be saved, loaded, and deleted by operating the instrument.\u003cbr\u003e-1. Date and time\u003cbr\u003e-2. Resistance value, voltage value, and temperature\u003cbr\u003e-3. Comparator threshold value and judgment result\u003cbr\u003e\u003cbr\u003e2. Profile information: Profile information can be saved, loaded, and deleted using a supported application (GENNECT Cross or GENNECT One).\u003cbr\u003e-1. Profile numbers: 1 to 100 (Data (2), (3), and (4) below are saved for each profile number)\u003cbr\u003e-2. Location: User-defined comment such as location of UPS\u003cbr\u003e-3. Device information: User-defined comment such as UPS management number\u003cbr\u003e-4. Battery number: 1 to 500 (start number, end number)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_9 col_0\"\u003eMeasurement Navigator\u003c\/th\u003e\n\u003ctd class=\"row_9 col_1\" colspan=\"6\"\u003eOperation: Announces the next battery number to be measured via a screen display and audio guidance.\u003cbr\u003eAudio output is generated by a connected mobile device when using the Z3210 and a supported application (GENNECT Cross).\u003cbr\u003ePreparations: Profile information that's been registered with a supported application (GENNECT Cross or GENNECT One) must be transferred to the instrument.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_10 col_0\"\u003eCommunication interface\u003c\/th\u003e\n\u003ctd class=\"row_10 col_1\" colspan=\"6\"\u003eUSB\u003cbr\u003eBluetooth® wireless communications (when Z3210 installed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_11 col_0\"\u003eOther functions\u003c\/th\u003e\n\u003ctd class=\"row_11 col_1\" colspan=\"6\"\u003eTemperature measurement (-10.0 to 60.0 °C), Zero-adjustment, Hold, Auto-hold, Auto-memory, Auto-power-save, Clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_12 col_0\"\u003ePower supply\u003c\/th\u003e\n\u003ctd class=\"row_12 col_1\" colspan=\"6\"\u003eLR6 (size AA) alkaline battery ×8\u003cbr\u003eRated supply voltage: 1.5 V DC × 8\u003cbr\u003e(Nickel metal hydride batteries may be used. However, the battery life display is not supported in this configuration.)\u003cbr\u003eContinuous operating time: Approx. 8.3 hr. (without Z3210 installed), Approx. 8.2 hr. (with Z3210 installed and wireless communications active)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_13 col_0\"\u003eDimensions and mass\u003c\/th\u003e\n\u003ctd class=\"row_13 col_1\" colspan=\"6\"\u003e199 mm (7.83 in)W × 132 mm (5.20 in)H × 60.6 mm (2.39 in)D (with protector), 960 g (33.9 oz) (including batteries and protector)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"odd\"\u003e\n\u003cth class=\"row_14 col_0\"\u003eIncluded accessories\u003c\/th\u003e\n\u003ctd class=\"row_14 col_1\" colspan=\"6\"\u003eCarrying Case C1014 ×1, Protector Z5041 ×1, Fuse Set Z5050 ×1, 0 Adj Board ×1, Neck strap ×1, USB cable ×1, AA alkaline battery (LR6) ×8, User Manual ×1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"even\"\u003e\n\u003cth class=\"row_15 col_0\"\u003e　\u003c\/th\u003e\n\u003ctd class=\"row_15 col_1\"\u003eInstrument only\u003c\/td\u003e\n\u003ctd class=\"row_15 col_2\"\u003eWith Pin Type Lead 9465-10\u003c\/td\u003e\n\u003ctd class=\"row_15 col_3\" colspan=\"4\"\u003eWith Pin Type Lead L2020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hioki-nz","offers":[{"title":"Default Title","offer_id":47239483654315,"sku":null,"price":4600.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0765\/7789\/8667\/files\/BT3554-50__3png_d0bdbf8b-24f8-4ed5-91a8-1a3937a3178d.png?v=1781656590"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0765\/7789\/8667\/collections\/Battery_Testers.png?v=1781665576","url":"https:\/\/hioki.nz\/collections\/battery-test-equipment.oembed","provider":"Hioki NZ","version":"1.0","type":"link"}