PQ3198-94

PQ3198-94

$17,960.00 NZD
Sale price  $17,960.00 NZD Regular price 
Skip to product information
PQ3198-94
1/4

PQ3198-94

Investigate Power Characteristics and Analyze the Causes of Problems

$17,960.00 NZD
Sale price  $17,960.00 NZD Regular price 

The PQ3198-94 kit is based on the PQ3198 including its standard accessories plus all necessary additional accessories that enable professionals to perform high current measurements up to 6000 A in high power electrical systems. It offers a complete solution for monitoring and analyzing power quality.The PQ3198 main unit supports both AC and DC measurements, complies with the IEC61000-4-30 Class A standard and measures voltage fluctuations, transients, harmonics and inrush currents. Ideal for applications in renewable energy systems, electric vehicle charging stations and power controllers, the analyzer with its 4 isolated voltage channels enables simultaneous measurements across multiple circuits.

Technical details:

  • Measuring channels: 4 voltage channels, 4 current channels
  • Voltage measuring range: 1 V to 1000 V AC/DC, ±6000 V peak
  • Current measuring range: Up to 6000 A (with suitable current sensor)
  • Frequency range: DC, 0.1 Hz to 700 kHz
  • Basic accuracy: Voltage ±0.1 %, current ±0.1 % (with sensor)
  • Event detection: transients, voltage increases, voltage drops, interruptions, frequency fluctuations
  • Standard compliance: IEC61000-4-30 Class A
  • Display: 6.5-inch TFT colour display
  • Power supply: AC adapter Z1002, battery packs Z1003 (up to 3 hours operation)
  • Dimensions: 264 mm (W) × 150 mm (H) × 68 mm (D) - Weight: 2.6 kg

Technical details PQ3198-94 Kit:

  • Flexible current sensors (CT7045):
  • Rated measuring current: 6000 A AC
  • Measuring range: 600 A / 6000 A AC
  • Max. permissible input: 10000 A continuous (at 6000 A, 45 to 66 Hz, requires derating)
  • Bandwidth: 10 Hz to 50 kHz (±3 dB)
  • Accuracy: ±1.5 % F.S., ±0.25 % F.S.
  • Max. rated voltage to earth: 600 V (CAT IV), 1000 V (CAT III)
  • Loop diameter: 180 mm
  • Output connection: Hioki PL14
  • Operating temperature: -25°C to 65°C

Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

Measurement line type Single-phase 2-wire, Single-phase 3-wire, Three-phase 3-wire or Three-phase 4-wire plus one extra input channel for voltage, current, power measurement (AC or DC measurement)
Voltage ranges Voltage measurement: 600.00 V rms
Transient measurement 6.0000 kV peak
Current ranges 500.00 mA to 5.0000 kA AC (depends on current sensor in use)
Power ranges 300.00 W to 3.0000 MW (determined automatically based on voltage and current range in use)
Basic accuracy Voltage: ±0.1% of nominal voltage
Current: ±0.1 % rdg. ±0.1 % f.s. + current sensor accuracy
Active power: ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy
Measurement items 1. Transient voltage : 2 MHz sampling
2. Frequency cycle : Calculated as one cycle, 40 to 70 Hz
3. Voltage (1/2) RMS: one cycle calculation refreshed every half cycle
Current (1/2) RMS: half-cycle calculation
4. Voltage swell, Voltage dips, Voltage interruption
5. Inrush current
6. Voltage waveform comparison
7. Instantaneous flicker value: As per IEC61000-4-15
8. 200 ms frequency: Calculated as 10 or 12 cycles,40 to 70 Hz
9. 10 sec frequency: Calculated as the whole-cycle time during the specified 10 s period, 40 to 70 Hz
10. Voltage waveform peak, Current waveform peak
11. Voltage, Current, Active power, Apparent power, Reactive power, Active energy, Reactive energy, Power factor, Displacement power factor, Voltage unbalance factor, Current unbalance factor, and efficiency
12. High-order harmonic* component (voltage/ current): 2 kHz to 80 kHz
*Supraharmonic
13. Harmonic/ Harmonic phase angle (voltage/ current), Harmonic power: 0th to 50 th orders
14. Harmonic voltage-current phase angle: 1th to 50 th orders
15. Total harmonic distortion factor (voltage/ current)
16. Inter harmonic (voltage/ current): 0.5 th to 49.5 th order
17. K Factor (multiplication factor)
18. IEC Flicker, Δ V10 Flicker
19. Mains signaling voltage
Record Repeated ON: 1 year, Maximum recording event: 9999 × 366 days (up to 9999 events per day)
Repeated off: 35 days, maximum recording event: 9999 events
Interfaces SD/SDHC memory card, LAN (HTTP server function / FTP function), USB2.0 (for communication)
Display 6.5-inch TFT color LCD (640 × 480 dots)
Power supply AC adapter Z1002 (100 V to 240 V AC, 50/60 Hz, rated current 1.7 A), Battery Pack Z1003 (Continuous use: 180 minutes, Charging time: Max. 5 hr 30 m with AC adapter)
Dimensions and mass 300 mm (11.81 in)W × 211 mm (8.31 in)H × 68 mm (2.68 in)D, 2.6 kg (91.7 oz) (including Battery Pack Z1003)
Included accessories Instruction manual ×1, Measurement guide ×1, Voltage Cord L1000 ×1 set (Red/ Yellow/ Blue/ Gray each 1, Black 4, 3m (9.84ft) length, Alligator clip ×8), Spiral tube x20, Color clip, AC Adapter Z1002 ×1, Strap ×1, USB cable (1 m 3.28 ft length) ×1, Battery pack Z1003 ×1, SD Memory Card 2GB Z4001 ×1, Flexible Current Sensors CT7045 (4 units)